How to configure led status in r2x



For devices with single button - E21/ R20/ R23/ R26:
Users can control the call button area’s LED.

Go to Intercom - LED Setting to configure.
State: There is five states: Normal, Offline, Calling, Talking and Receiving.
Color Off: The default status is OFF.
Color On: It can support three color: Red, Green, Blue.
Blink Mode: To setup the different blink frequency.


LED Status
LED Control: Users can also use HTTP command to remote control the LED status.

LED control
The format for the HTTP command is like:
http://PhoneIP/fcgi/do?action=LedAction&State=1&Color=1&Mode=2500


State: 1=Idle; 2=OffLine; 3=Calling; 4=Talking; 5=Receiving;
Color: 1=Green; 2=Blue; 3=Red;
Mode: 0=Always On; 1=Always Off; 500/1000/1500/2000/25000/3000

The default LED status: LED Status



For devices with multiple numeric keyboard - R27:
Users can control three parts’ LED, screen, keypad and card area.

Go to Intercom - LED Setting to configure.
Users can also setup the valid time. For example, start time from 18 to 23 means the LED will light up from 6pm to 11pm.


LED control
For devices with touch screen - R29:
Users can control card area’s LED.

Go to Intercom - LED Setting to configure.
Users can also setup the valid time. For example, start time from 18 to 23 means the LED will light up from 6pm to 11pm.


LED control